Inspection Procedure

  1. INSPECT FUSE (AM2) 
    1. Remove the AM2 fuse from the cowl side J/B RH.
    2. Measure the resistance of the fuse.

      Standard resistance: 

      Below 1 Ω 

    NG: REPLACE FUSE 

    OK: Go to next step 

  2. CHECK WIRE HARNESS (POWER SOURCE CONTROL ECU BATTERY AND BODY GROUND) 
    1. Disconnect the K73 ECU connector.
    2. Measure the voltage and resistance of the wire harness side connector.

      Standard voltage 

      TESTER CONNECTION SPECIFIED CONDITION CHART

      Tester Connection Specified Condition
      K73-33 (AM1) - Body ground 10 to 14 V
      K73-12 (AM2) - Body ground 10 to 14 V

      Standard resistance 

      TESTER CONNECTION SPECIFIED CONDITION CHART

      Tester Connection Specified Condition
      K73-6 (GND2) - Body ground 10 kΩ or higher
    Fig 1: Identifying K73 ECU Connector
    G05287738Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

    NG: REPAIR OR REPLACE HARNESS AND CONNECTOR 

    OK: REPLACE POWER SOURCE CONTROL ECU