Seat Heater Control: Inspection
- INSPECT FRONT SEAT HEATER CONTROL LH
- Disconnect the seat heater control LH connector.
- Measure the voltage and resistance according to the value(s) in the table below.
Standard resistance
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Condition Specified Condition U16-6 (E) - Body ground Always Below 1 Ω Standard voltage
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Condition Specified Condition U16-1 (SWL) - U16-6 (E) Engine switch on (IG), seat heater switch OFF → ON 0 V → 10 to 14 V U16-4 (B) - U16-6 (E) Engine switch off → on (IG) 0 V → 10 to 14 V - Reconnect the seat heater control LH connector.
- Measure the voltage according to the value(s) in the table below.
Standard voltage
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Condition Specified Condition U16-5 (THL) - U16-6 (E) Engine switch on (IG), seat heater switch volume 1 → 3 Gradual increase 0 V → 10 to 14 V
- INSPECT FRONT SEAT HEATER CONTROL RH
- Disconnect the seat heater control RH connector.
- Measure the voltage and resistance according to the value(s) in the table below.
Standard resistance
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Condition Specified Condition T18-6 (E) - Body ground Always Below 1 Ω Standard voltage
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Condition Specified Condition T18-1 (SWR) - T18-6 (E) Engine switch on (IG), seat heater switch OFF → ON 0 V → 10 to 14 V T18-4 (B1) - T18-6 (E) Engine switch off → on (IG) 0 V → 10 to 14 V - Reconnect the seat heater control RH connector.
- Measure the voltage according to the value(s) in the table below.
Standard voltage
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Condition Specified Condition T18-5 (THR) - T18-6 (E) Engine switch on (IG), seat heater switch volume 1 → 3 Gradual increase 0 V → 10 to 14 V