Power Seat Switch: Inspection
- INSPECT FRONT POWER SEAT SWITCH LH (w/ Seat Position Memory System)
- Measure the resistance between the specified terminals when each switch is operated.
Standard resistance (Slide switch)
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Switch Condition Specified Condition U3-5 (+B) - U3-2 (SLD+) FRONT Below 1 Ω U3-1 (GND) - U3-3 (SLD-) FRONT Below 1 Ω U3-5 (+B) - U3-3 (SLD-) FRONT 10 kΩ or higher U3-1 (GND) - U3-2 (SLD+) FRONT 10 kΩ or higher U3-1 (GND) - U3-2 (SLD+) OFF Below 1 Ω U3-1 (GND) - U3-3 (SLD-) OFF Below 1 Ω U3-5 (+B) - U3-2 (SLD+) OFF 10 kΩ or higher U3-5 (+B) - U3-3 (SLD-) OFF 10 kΩ or higher U3-5 (+B) - U3-3 (SLD-) REAR Below 1 Ω U3-1 (GND) - U3-2 (SLD+) REAR Below 1 Ω U3-5 (+B) - U3-2 (SLD+) REAR 10 kΩ or higher U3-1 (GND) - U3-3 (SLD-) REAR 10 kΩ or higher Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
Standard resistance (Front vertical switch)
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Switch Condition Specified Condition U3-5 (+B) - U3-6 (FRV+) UP Below 1 Ω U3-1 (GND) - U3-4 (FRV-) UP Below 1 Ω U3-5 (+B) - U3-4 (FRV-) UP 10 kΩ or higher U3-1 (GND) - U3-6 (FRV+) UP 10 kΩ or higher U3-1 (GND) - U3-6 (FRV+) OFF Below 1 Ω U3-1 (GND) - U3-4 (FRV-) OFF Below 1 Ω U3-5 (+B) - U3-6 (FRV+) OFF 10 kΩ or higher U3-5 (+B) - U3-4 (FRV-) OFF 10 kΩ or higher U3-5 (+B) - U3-4 (FRV-) DOWN Below 1 Ω U3-1 (GND) - U3-6 (FRV+) DOWN Below 1 Ω U3-5 (+B) - U3-6 (FRV+) DOWN 10 kΩ or higher U3-1 (GND) - U3-4 (FRV-) DOWN 10 kΩ or higher Standard resistance (Lifter switch)
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Switch Condition Specified Condition U3-5 (+B) - U3-7 (LFT+) UP Below 1 Ω U3-1 (GND) - U3-9 (LFT-) UP Below 1 Ω U3-5 (+B) - U3-9 (LFT-) UP 10 kΩ or higher U3-1 (GND) - U3-7 (LFT+) UP 10 kΩ or higher U3-1 (GND) - U3-7 (LFT+) OFF Below 1 Ω U3-1 (GND) - U3-9 (LFT-) OFF Below 1 Ω U3-5 (+B) - U3-7 (LFT+) OFF 10 kΩ or higher U3-5 (+B) - U3-9 (LFT-) OFF 10 kΩ or higher U3-5 (+B) - U3-9 (LFT-) DOWN Below 1 Ω U3-1 (GND) - U3-7 (LFT+) DOWN Below 1 Ω U3-5 (+B) - U3-7 (LFT+) DOWN 10 kΩ or higher U3-1 (GND) - U3-9 (LFT-) DOWN 10 kΩ or higher Standard resistance (Reclining switch)
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Switch Condition Specified Condition U3-5 (+B) - U3-8 (RCL+) FRONT Below 1 Ω U3-1 (GND) - U3-10 (RCL-) FRONT Below 1 Ω U3-5 (+B) - U3-10 (RCL-) FRONT 10 kΩ or higher U3-1 (GND) - U3-8 (RCL+) FRONT 10 kΩ or higher U3-1 (GND) - U3-8 (RCL+) OFF Below 1 Ω U3-1 (GND) - U3-10 (RCL-) OFF Below 1 Ω U3-5 (+B) - U3-8 (RCL+) OFF 10 kΩ or higher U3-5 (+B) - U3-10 (RCL-) OFF 10 kΩ or higher U3-5 (+B) - U3-10 (RCL-) REAR Below 1 Ω U3-1 (GND) - U3-8 (RCL+) REAR Below 1 Ω U3-5 (+B) - U3-8 (RCL+) REAR 10 kΩ or higher U3-1 (GND) - U3-10 (RCL-) REAR 10 kΩ or higher If the result is not as specified, replace the front power seat switch LH.
- Measure the resistance between the specified terminals when each switch is operated.
- INSPECT FRONT POWER SEAT SWITCH LH (w/o Seat Position Memory System)
- Measure the resistance between the specified terminals when each switch is operated.
Standard resistance (Slide switch)
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Switch Condition Specified Condition U13-1 (B) - U13-9 (SLDF) FRONT Below 1 Ω U13-4 (E) - U13-6 (SLDR) FRONT Below 1 Ω U13-1 (B) - U13-6 (SLDR) FRONT 10 kΩ or higher U13-4 (E) - U13-9 (SLDF) FRONT 10 kΩ or higher U13-4 (E) - U13-6 (SLDR) OFF Below 1 Ω U13-4 (E) - U13-9 (SLDF) OFF Below 1 Ω U13-1 (B) - U13-6 (SLDR) OFF 10 kΩ or higher U13-1 (B) - U13-9 (SLDF) OFF 10 kΩ or higher U13-1 (B) - U13-6 (SLDR) REAR Below 1 Ω U13-4 (E) - U13-9 (SLDF) REAR Below 1 Ω U13-1 (B) - U13-9 (SLDF) REAR 10 kΩ or higher U13-4 (E) - U13-6 (SLDR) REAR 10 kΩ or higher Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
Standard resistance (Front vertical switch)
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Switch Condition Specified Condition U13-1 (B) - U13-10 (FUP) UP Below 1 Ω U13-4 (E) - U13-5 (FDWN) UP Below 1 Ω U13-1 (B) - U13-5 (FDWN) UP 10 kΩ or higher U13-4 (E) - U13-10 (FUP) UP 10 kΩ or higher U13-4 (E) - U13-5 (FDWN) OFF Below 1 Ω U13-4 (E) - U13-10 (FUP) OFF Below 1 Ω U13-1 (B) - U13-5 (FDWN) OFF 10 kΩ or higher U13-1 (B) - U13-10 (FUP) OFF 10 kΩ or higher U13-1 (B) - U13-5 (FDWN) DOWN Below 1 Ω U13-4 (E) - U13-10 (FUP) DOWN Below 1 Ω U13-1 (B) - U13-10 (FUP) DOWN 10 kΩ or higher U13-4 (E) - U13-5 (FDWN) DOWN 10 kΩ or higher Standard resistance (Lifter switch)
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Switch Condition Specified Condition U13-1 (B) - U13-7 (RUP) UP Below 1 Ω U13-4 (E) - U13-8 (RDWN) UP Below 1 Ω U13-1 (B) - U13-8 (RDWN) UP 10 kΩ or higher U13-4 (E) - U13-7 (RUP) UP 10 kΩ or higher U13-4 (E) - U13-7 (RUP) OFF Below 1 Ω U13-4 (E) - U13-8 (RDWN) OFF Below 1 Ω U13-1 (B) - U13-7 (RUP) OFF 10 kΩ or higher U13-1 (B) - U13-8 (RDWN) OFF 10 kΩ or higher U13-1 (B) - U13-8 (RDWN) DOWN Below 1 Ω U13-4 (E) - U13-7 (RUP) DOWN Below 1 Ω U13-1 (B) - U13-7 (RUP) DOWN 10 kΩ or higher U13-4 (E) - U13-8 (RDWN) DOWN 10 kΩ or higher Standard resistance (Reclining switch)
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Switch Condition Specified Condition U13-1 (B) - U13-3 (RCLF) FRONT Below 1 Ω U13-4 (E) - U13-2 (RCLR) FRONT Below 1 Ω U13-1 (B) - U13-2 (RCLR) FRONT 10 kΩ or higher U13-4 (E) - U13-3 (RCLF) FRONT 10 kΩ or higher U13-4 (E) - U13-2 (RCLR) OFF Below 1 Ω U13-4 (E) - U13-3 (RCLF) OFF Below 1 Ω U13-1 (B) - U13-3 (RCLF) OFF 10 kΩ or higher U13-1 (B) - U13-2 (RCLR) OFF 10 kΩ or higher U13-1 (B) - U13-2 (RCLR) REAR Below 1 Ω U13-4 (E) - U13-3 (RCLF) REAR Below 1 Ω U13-1 (B) - U13-3 (RCLF) REAR 10 kΩ or higher U13-4 (E) - U13-2 (RCLR) REAR 10 kΩ or higher If the result is not as specified, replace the front power seat switch LH.
- Measure the resistance between the specified terminals when each switch is operated.
- INSPECT FRONT POWER SEAT SWITCH RH (w/ Seat Position Memory System)
- Measure the resistance between the specified terminals when each switch is operated.
Standard resistance (Slide switch)
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Switch Condition Specified Condition T6-5 (+B) - T6-2 (SLD+) FRONT Below 1 Ω T6-1 (GND) - T6-3 (SLD-) FRONT Below 1 Ω T6-5 (+B) - T6-3 (SLD-) FRONT 10 kΩ or higher T6-1 (GND) - T6-2 (SLD+) FRONT 10 kΩ or higher T6-1 (GND) - T6-2 (SLD+) OFF Below 1 Ω T6-1 (GND) - T6-3 (SLD-) OFF Below 1 Ω T6-5 (+B) - T6-2 (SLD+) OFF 10 kΩ or higher T6-5 (+B) - T6-3 (SLD-) OFF 10 kΩ or higher T6-5 (+B) - T6-3 (SLD-) REAR Below 1 Ω T6-1 (GND) - T6-2 (SLD+) REAR Below 1 Ω T6-5 (+B) - T6-2 (SLD+) REAR 10 kΩ or higher T6-1 (GND) - T6-3 (SLD-) REAR 10 kΩ or higher Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
Standard resistance (Front vertical switch)
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Switch Condition Specified Condition T6-5 (+B) - T6-6 (FRV+) UP Below 1 Ω T6-1 (GND) - T6-4 (FRV-) UP Below 1 Ω T6-5 (+B) - T6-4 (FRV-) UP 10 kΩ or higher T6-1 (GND) - T6-6 (FRV+) UP 10 kΩ or higher T6-1 (GND) - T6-6 (FRV+) OFF Below 1 Ω T6-1 (GND) - T6-4 (FRV-) OFF Below 1 Ω T6-5 (+B) - T6-6 (FRV+) OFF 10 kΩ or higher T6-5 (+B) - T6-4 (FRV-) OFF 10 kΩ or higher T6-5 (+B) - T6-4 (FRV-) DOWN Below 1 Ω T6-1 (GND) - T6-6 (FRV+) DOWN Below 1 Ω T6-5 (+B) - T6-6 (FRV+) DOWN 10 kΩ or higher T6-1 (GND) - T6-4 (FRV-) DOWN 10 kΩ or higher Standard resistance (Lifter switch)
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Switch Condition Specified Condition T6-5 (+B) - T6-7 (LFT+) UP Below 1 Ω T6-1 (GND) - T6-9 (LFT-) UP Below 1 Ω T6-5 (+B) - T6-9 (LFT-) UP 10 kΩ or higher T6-1 (GND) - T6-7 (LFT+) UP 10 kΩ or higher T6-1 (GND) - T6-7 (LFT+) OFF Below 1 Ω T6-1 (GND) - T6-9 (LFT-) OFF Below 1 Ω T6-5 (+B) - T6-7 (LFT+) OFF 10 kΩ or higher T6-5 (+B) - T6-9 (LFT-) OFF 10 kΩ or higher T6-5 (+B) - T6-9 (LFT-) DOWN Below 1 Ω T6-1 (GND) - T6-7 (LFT+) DOWN Below 1 Ω T6-5 (+B) - T6-7 (LFT+) DOWN 10 kΩ or higher T6-1 (GND) - T6-9 (LFT-) DOWN 10 kΩ or higher Standard resistance (Reclining switch)
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Switch Condition Specified Condition T6-5 (+B) - T6-8 (RCL+) FRONT Below 1 Ω T6-1 (GND) - T6-10 (RCL-) FRONT Below 1 Ω T6-5 (+B) - T6-10 (RCL-) FRONT 10 kΩ or higher T6-1 (GND) - T6-8 (RCL+) FRONT 10 kΩ or higher T6-1 (GND) - T6-8 (RCL+) OFF Below 1 Ω T6-1 (GND) - T6-10 (RCL-) OFF Below 1 Ω T6-5 (+B) - T6-8 (RCL+) OFF 10 kΩ or higher T6-5 (+B) - T6-10 (RCL-) OFF 10 kΩ or higher T6-5 (+B) - T6-10 (RCL-) REAR Below 1 Ω T6-1 (GND) - T6-8 (RCL+) REAR Below 1 Ω T6-5 (+B) - T6-8 (RCL+) REAR 10 kΩ or higher T6-1 (GND) - T6-10 (RCL-) REAR 10 kΩ or higher If the result is not as specified, replace the front power seat switch RH.
- Measure the resistance between the specified terminals when each switch is operated.
- INSPECT FRONT POWER SEAT SWITCH RH (w/o Seat Position Memory System)
- Measure the resistance between the specified terminals when each switch is operated.
Standard resistance (Slide switch)
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Switch Condition Specified Condition T14-1 (B) - T14-9 (SLDF) FRONT Below 1 Ω T14-4 (E) - T14-6 (SLDR) FRONT Below 1 Ω T14-1 (B) - T14-6 (SLDR) FRONT 10 kΩ or higher T14-4 (E) - T14-9 (SLDF) FRONT 10 kΩ or higher T14-4 (E) - T14-6 (SLDR) OFF Below 1 Ω T14-4 (E) - T14-9 (SLDF) OFF Below 1 Ω T14-1 (B) - T14-6 (SLDR) OFF 10 kΩ or higher T14-1 (B) - T14-9 (SLDF) OFF 10 kΩ or higher T14-1 (B) - T14-6 (SLDR) REAR Below 1 Ω T14-4 (E) - T14-9 (SLDF) REAR Below 1 Ω T14-1 (B) - T14-9 (SLDF) REAR 10 kΩ or higher T14-4 (E) - T14-6 (SLDR) REAR 10 kΩ or higher Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
Standard resistance (Front vertical switch)
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Switch Condition Specified Condition T14-1 (B) - T14-5 (FUP) UP Below 1 Ω T14-4 (E) - T14-10 (FDWN) UP Below 1 Ω T14-1 (B) - T14-10 (FDWN) UP 10 kΩ or higher T14-4 (E) - T14-5 (FUP) UP 10 kΩ or higher T14-4 (E) - T14-10 (FDWN) OFF Below 1 Ω T14-4 (E) - T14-5 (FUP) OFF Below 1 Ω T14-1 (B) - T14-10 (FDWN) OFF 10 kΩ or higher T14-1 (B) - T14-5 (FUP) OFF 10 kΩ or higher T14-1 (B) - T14-10 (FDWN) DOWN Below 1 Ω T14-4 (E) - T14-5 (FUP) DOWN Below 1 Ω T14-1 (B) - T14-5 (FUP) DOWN 10 kΩ or higher T14-4 (E) - T14-10 (FDWN) DOWN 10 kΩ or higher Standard resistance (Lifter switch)
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Switch Condition Specified Condition T14-1 (B) - T14-8 (RUP) UP Below 1 Ω T14-4 (E) - T14-7 (RDWN) UP Below 1 Ω T14-1 (B) - T14-7 (RDWN) UP 10 kΩ or higher T14-4 (E) - T14-8 (RUP) UP 10 kΩ or higher T14-4 (E) - T14-8 (RUP) OFF Below 1 Ω T14-4 (E) - T14-7 (RDWN) OFF Below 1 Ω T14-1 (B) - T14-8 (RUP) OFF 10 kΩ or higher T14-1 (B) - T14-7 (RDWN) OFF 10 kΩ or higher T14-1 (B) - T14-7 (RDWN) DOWN Below 1 Ω T14-4 (E) - T14-8 (RUP) DOWN Below 1 Ω T14-1 (B) - T14-8 (RUP) DOWN 10 kΩ or higher T14-4 (E) - T14-7 (RDWN) DOWN 10 kΩ or higher Standard resistance (Reclining switch)
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Switch Condition Specified Condition T14-1 (B) - T14-3 (RCLF) FRONT Below 1 Ω T14-4 (E) - T14-2 (RCLR) FRONT Below 1 Ω T14-1 (B) - T14-2 (RCLR) FRONT 10 kΩ or higher T14-4 (E) - T14-3 (RCLF) FRONT 10 kΩ or higher T14-4 (E) - T14-2 (RCLR) OFF Below 1 Ω T14-4 (E) - T14-3 (RCLF) OFF Below 1 Ω T14-1 (B) - T14-3 (RCLF) OFF 10 kΩ or higher T14-1 (B) - T14-2 (RCLR) OFF 10 kΩ or higher T14-1 (B) - T14-2 (RCLR) REAR Below 1 Ω T14-4 (E) - T14-3 (RCLF) REAR Below 1 Ω T14-1 (B) - T14-3 (RCLF) REAR 10 kΩ or higher T14-4 (E) - T14-2 (RCLR) REAR 10 kΩ or higher If the result is not as specified, replace the front power seat switch RH.
- Measure the resistance between the specified terminals when each switch is operated.