Front Door Lock: Inspection
- INSPECT FRONT DOOR LOCK LH ASSEMBLY
- Remove the front door lock assembly LH.
- Check operation of the door lock motor.
- Check operation of the door key lock and unlock switch.
- Measure the resistance according to the value(s) in the table below.
Standard resistance
TESTER CONNECTION SPECIFIED CONDITIONTester Connection Condition Specified Condition 7 - 9 ON (Door lock set to LOCK) Below 1 Ω 7 - 9
7 - 10OFF (Free) 10 kΩ or higher 7 - 10 ON (Door lock set to UNLOCK) Below 1 Ω
- Measure the resistance according to the value(s) in the table below.
- Check operation of the door unlock detection switch.
- Measure the resistance according to the value(s) in the table below.
Standard resistance
TESTER CONNECTION SPECIFIED CONDITIONTester Connection Measurement Condition Door Lock Condition Specified Condition 7 - 8 Battery positive (+) → Terminal 4
Battery negative (-) → Terminal 1Lock 10 kΩ or higher 7-8 Battery positive (+) → Terminal 1
Battery negative (-) → Terminal 4Unlock Below 1 Ω
- Measure the resistance according to the value(s) in the table below.
- INSPECT FRONT DOOR LOCK RH ASSEMBLY
- Remove the front door lock assembly RH.
- Check operation of the door lock motor.
- Check operation of the door unlock detection switch.
- Measure the resistance according to the value(s) in the table below.
Standard resistance
TESTER CONNECTION SPECIFIED CONDITIONTester Connection Measurement Condition Door Lock Condition (Specified Condition) 7 - 8 Battery positive (+) → Terminal 4
Battery negative (-) → Terminal 1LOCK 10 kΩ or higher 7 - 8 Battery positive (+) → Terminal 1
Battery negative (-) → Terminal 4UNLOCK Below 1 Ω
- Measure the resistance according to the value(s) in the table below.