Typical Enabling Conditions
All:
TYPICAL ENABLING CONDITIONS - ALL
| The monitor will run whenever this DTC is not present. | None |
|---|---|
| Engine switch | ON |
| Battery voltage | 10.5 V or more |
Condition (C):
TYPICAL ENABLING CONDITIONS - CONDITION (C)
| One of the following conditions is met: | Condition (a), (b), (c) or (d) |
|---|---|
| (a) Park Neutral position switch | ON |
| (b) Park position switch | ON |
| (c) Neutral position switch | ON |
| (d) R range position switch | ON |