LEMON Manuals: Even more car manuals for everyone
Home >> Lexus >> 2006 >> LX 470 >> Repair and Diagnosis >> Transmission >> Transfer Case >> Transfer >> Rear Extension Housing >> Inspection

Rear Extension Housing: Inspection

  1. INSPECT OIL PUMP DRIVEN ROTOR BODY CLEARANCE 
    1. Install the drive rotor and driven rotor to the rear extension housing.
    2. Using a feeler gauge, measure the body clearance between the drive rotor and extension housing.
    Fig 1: Measuring Body Clearance Between Drive Rotor And Extension Housing
    G04063217Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

    Standard clearance: 0.08 to 0.17 mm (0.0031 to 0.0067 in.) 

    Maximum clearance: 0.17 mm (0.0067 in.) 

    If the body clearance is greater than the maximum, replace the drive rotor and drive rotor.

  2. INSPECT OIL PUMP DRIVE ROTOR TIP CLEARANCE 
    1. Using a feeler gauge, measure the tip clearance between the drive rotor and driven rotor.
    Fig 2: Measuring Tip Clearance Between Drive Rotor And Driven Rotor
    G04063218Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

    Standard clearance: 0.05 to 0.15 mm (0.0020 to 0.0059 in.) 

    Maximum clearance: 0.15 mm (0.0059 in.) 

    If the tip clearance is greater than the maximum, replace the drive rotor and driven rotor.

  3. INSPECT OIL PUMP SIDE CLEARANCE 
    1. Using a steel straightedge and feeler gauge, measure the side clearance of the oil pump.
    Fig 3: Measuring Side Clearance Of Oil Pump
    G04063219Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

    Standard clearance: 0.03 to 0.10 mm (0.0012 to 0.0039 in.) 

    Maximum clearance: 0.10 mm (0.0039 in.) 

    If the side clearance is greater than the maximum, replace the drive rotor and driven rotor.