LEMON Manuals: Even more car manuals for everyone
Home >> Lexus >> 2006 >> LX 470 >> Repair and Diagnosis (Single Page) >> Engine Performance >> Remove, Overhaul & Install >> Engine Control System (2UZ-FE) - DTC P0327 - P0630 >> DTC P043E: Evaporative Emission System Leak Detection Reference Orifice Low Flow; DTC P043F: Evaporative Emission System Reference Orifice High Flow >> Typical Enabling Conditions

Typical Enabling Conditions

TYPICAL ENABLING CONDITIONS CHART

Enable conditions of EVAP key-OFF monitor
P043E (Reference orifice - low flow)
P043F (Reference orifice - high flow)
P0441 (Purge VSV - stuck open)
P0441 (Purge VSV - stuck close)
P0451 (Canister pressure sensor - noise)
P0455 (EVAP gross leak)
P0456 (EVAP 0.02 inch leak)
P2401 (Leak detection pump - stuck OFF)
P2402 (Leak detection pump - stuck ON)
P2419 (Vent valve - stuck ON)
P2420 (Vent valve - stuck OFF)
Atmospheric pressure 70 to 110 kPa (525 to 825 mmHg)
Battery voltage 10.5 V or higher
Vehicle speed 4 km/h (2.5 mph) or less
Ignition switch OFF
Time after key off 5 or 7 or 9.5 hours
Canister pressure sensor malfunction (P0450, P0452, P0453) Not detected
Purge VSV Not operated by scan tool
Vent valve Not operated by scan tool
Leak detection pump Not operated by scan tool
Both of the following conditions 1 and 2 are met before key off -
1. Duration that vehicle has been driven 5 minutes or more
2. EVAP purge operation Performed
ECT 4.4 to 35°C (40 to 95°F)
IAT 4.4 to 35°C (40 to 95°F)
  1. Key-off monitor sequence 1 to 8 
  1. Atmospheric pressure measurement 
    TYPICAL ENABLING CONDITIONS CHART

    Next sequence is run if the following condition is met -
    Atmospheric pressure change Within 0.3 kPa (2.25 mmHg) in 1 second
  2. First reference pressure measurement 
    TYPICAL ENABLING CONDITIONS CHART

    Next sequence is run if the following conditions are met -
    EVAP pressure just after reference pressure measurement start -1 kPa (-7.5 mmHg) or lower
    Reference pressure -4.85 to -1.05 kPa (726 to 754 mmHg)
    Reference pressure Saturated within 60 seconds
  3. Vent valve stuck closed check 
    TYPICAL ENABLING CONDITIONS CHART

    Next sequence is run if the following condition is met -
    EVAP pressure change after vent valve is ON 0.3 kPa (2.25 mmHg) or more
  4. Vacuum introduction 
    TYPICAL ENABLING CONDITIONS CHART

    Next sequence is run if the following condition is met -
    EVAP pressure Saturated within 900 seconds
  5. Purge VSV stuck closed check 
    TYPICAL ENABLING CONDITIONS CHART

    Next sequence is run if the following condition is met -
    EVAP pressure change after purge valve is open 0.3 kPa (2.25 mmHg) or more
  6. Second reference pressure measurement 
    TYPICAL ENABLING CONDITIONS CHART

    Next sequence is run if the following conditions are met -
    EVAP pressure just after reference pressure measurement -1 kPa (-7.5 mmHg) or lower
    Reference pressure -4.85 to -1.05 kPa (726 to 754 mmHg)
    Reference pressure Saturated within 60 seconds
    Difference between first reference pressure Less than 0.7 kPa (5.25 mmHg)
  7. Leak check 
    TYPICAL ENABLING CONDITIONS CHART

    Next sequence is run if the following condition is met -
    EVAP pressure when vacuum introduction is complete Lower than second reference pressure
  8. Atmospheric pressure measurement 
TYPICAL ENABLING CONDITIONS CHART

EVAP monitor is complete if the following condition is met -
Atmospheric pressure difference between sequence 1 and 8 Within 0.3 kPa (2.25 mmHg)