Monitor Result

Refer to detailed information (see CHECKING MONITOR STATUS  ).

The test value and test limit information are described as shown in the following table. Check the monitor result and test values after performing the monitor driven pattern (refer to "CONFIRMATION DRIVING PATTERN  ").

Catalyst bank 1 - Using heated oxygen sensor on sensor 1 and 2 

MID DESCRIPTION CHART

MID TID Scaling Description of Test Value Minimum Test Limit Maximum Test Limit
$21 $A1 Multiply by 0.0003 [no dimension] Locus length ratio of heated oxygen sensor 1 and 2 Minimum test limit for catalyst Maximum test limit for catalyst
$21 $A2 Multiply by 0.0003 [no dimension] Voltage area ratio of heated oxygen sensor 1 and sensor 2 Minimum test limit for catalyst Maximum test limit for catalyst
$21 $A3 Multiply by 0.0003 [no dimension] Locus length ratio of heated oxygen sensor 1 and 2 Minimum test limit for catalyst Maximum test limit for catalyst
$21 $A4 Multiply by 0.0003 [no dimension] Heated oxygen sensor frequency ratio of sensor 1 and sensor 2 Minimum test limit for catalyst Maximum test limit for catalyst
$21 $A5 Multiply by 0.0003 [no dimension] Locus length ratio of heated oxygen sensor 1 and 2 Minimum test limit for catalyst Maximum test limit for catalyst
$21 $A6 Multiply by 0.0003 [no dimension] Voltage area ratio of heated oxygen sensor 1 and sensor 2 Minimum test limit for catalyst Maximum test limit for catalyst

Catalyst bank 2- Using heated oxygen sensor on sensor 1 and 2 

MID DESCRIPTION CHART

MID TID Scaling Description of Test Value Minimum Test Limit Maximum Test Limit
$22 $A1 Multiply by 0.0003 [no dimension] Locus length ratio of heated oxygen sensor 1 and 2 Minimum test limit for catalyst Maximum test limit for catalyst
$22 $A2 Multiply by 0.0003 [no dimension] Voltage area ratio of heated oxygen sensor 1 and sensor 2 Minimum test limit for catalyst Maximum test limit for catalyst
$22 $A3 Multiply by 0.0003 [no dimension] Locus length ratio of heated oxygen sensor 1 and 2 Minimum test limit for catalyst Maximum test limit for catalyst
$22 $A4 Multiply by 0.0003 [no dimension] Heated oxygen sensor frequency ratio of sensor 1 and sensor 2 Minimum test limit for catalyst Maximum test limit for catalyst
$22 $A5 Multiply by 0.0003 [no dimension] Locus length ratio of heated oxygen sensor 1 and 2 Minimum test limit for catalyst Maximum test limit for catalyst
$22 $A6 Multiply by 0.0003 [no dimension] Voltage area ratio of heated oxygen sensor 1 and sensor 2 Minimum test limit for catalyst Maximum test limit for catalyst