Inspection Procedure
- Check LH SEAT fuse.
- NG: CHECK FOR SHORT IN ALL THE HARNESS AND COMPONENTS CONNECTED TO THE LH SEAT FUSE, AND RE PAIR THEM.
- OK: Go to Next Step.
- Check continuity between terminal E, SGND of Power Seat Control ECU connector and body ground.
CHECK:
Measure resistance between terminal E, SGND of Power Seat Control ECU connector and body ground with connector being connected.
OK:
- Resistance: Continuity (Below 1 Ω)
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
- NG: Repair or replace harness or connector.
- OK: Go to Next Step.
- Check voltage between terminal B of Power Seat Control ECU connector and body ground.
CHECK:
Measure voltage between terminal B of Power Seat Control ECU connector and body ground with connector being connected.
OK:
- Voltage: 10 -14 V
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
- OK: Proceed to next circuit inspection shown on problem symptom table (See PROBLEM SYMPTOMS TABLE ).
- NG: Repair or replace harness or connector.