Monitor Result
Refer to CHECKING MONITOR STATUS for detailed information.
The test value and test limit information are described as shown in the following table. Check the monitor result and test values after performing the monitor drive pattern (refer to "confirmation monitor").
- MID (Monitor Identification Data) is assigned to each emission-related component.
- TID (Test Identification Data) is assigned to each emissions-related component.
- Scaling is used to calculate the test value indicated on generic OBDII scan tools.
HO2S bank 1 sensor 1
TEST VALUE AND LIMIT TABLE
| MID | TID | Scaling | Description of Test Value | Minimum Test Limit | Maximum Test Limit |
|---|---|---|---|---|---|
| $01 | $03 | Multiply by 0.001 [V] | Sensor voltage to define sensor status is Lean that is defined when sensor voltage is lower than this value | Sensor voltage to define sensor status is Lean | Sensor voltage to define sensor status is Lean |
| $01 | $04 | Multiply by 0.001 [V] | Sensor voltage to define sensor status is Rich that is defined when sensor voltage is lower than this value | Sensor voltage to define sensor status is Rich | Sensor voltage to define sensor status is Rich |
| $01 | $05 | Multiply by 0.001 [seconds] | Rich to Lean switch time | Minimum test limit | Maximum test limit |
| $01 | $06 | Multiply by 0.001 [seconds] | Lean to Rich switch time | Minimum test limit | Maximum test limit |
| $01 | $07 | Multiply by 0.005 [V] | Minimum sensor voltage | 0 V | Malfunction criterion |
| $01 | $08 | Multiply by 0.005 [V] | Maximum sensor voltage | Malfunction criterion | 1.0 V |
| $01 | $81 | Multiply by 0.001 [seconds] | Duration while sensor voltage stuck Lean or Rich | 0 | Malfunction criterion |
| $01 | $82 | Multiply by 0.001 [seconds] | Duration of one sensor frequency | Minimum test limit | Maximum test limit |
HO2S bank 2 sensor 1
TEST VALUE AND LIMIT TABLE
| MID | TID | Scaling | Description of Test Value | Minimum Test Limit | Maximum Test Limit |
|---|---|---|---|---|---|
| $05 | $03 | Multiply by 0.001 [V] | Sensor voltage to define sensor status is Lean that is defined when sensor voltage is lower than this value | Sensor voltage to define sensor status is Lean | Sensor voltage to define sensor status is Lean |
| $05 | $04 | Multiply by 0.001 [V] | Sensor voltage to define sensor status is Rich that is defined when sensor voltage is lower than this value | Sensor voltage to define sensor status is Rich | Sensor voltage to define sensor status is Rich |
| $05 | $05 | Multiply by 0.001 [seconds] | Rich to Lean switch time | Minimum test limit | Maximum test limit |
| $05 | $06 | Multiply by 0.001 [seconds] | Lean to Rich switch time | Minimum test limit | Maximum test limit |
| $05 | $07 | Multiply by 0.005 [V] | Minimum sensor voltage | 0 V | Malfunction criterion |
| $05 | $08 | Multiply by 0.005 [V] | Maximum sensor voltage | Malfunction criterion | 1.0 V |
| $05 | $81 | Multiply by 0.001 [seconds] | Duration while sensor voltage stuck Lean or Rich | 0 | Malfunction criterion |
| $05 | $82 | Multiply by 0.001 [seconds] | Duration of one sensor frequency | Minimum test limit | Maximum test limit |