LEMON Manuals: Even more car manuals for everyone
Home >> Lexus >> 2005 >> GX 470 >> Repair and Diagnosis >> External Pages >> Different car >> Section 4 (Automatic Transmission - Diagnostics) >> Pattern Select Switch Circuit (PWR Mode Switch) >> Inspection Procedure

Inspection Procedure

WARNING: This page is about a different car, the 2005 Lexus LX 470. However, it is still accessible from the selected car via links, so may be relevant.
  1. Check pattern select switch (PWR mode switch). 

    PREPARATION: 

    Disconnect the pattern select switch connector.

    CHECK: 

    Check continuity between terminals 3 and 5 of pattern select switch connector when the select switch is set to PWR and NORM positions.

    OK: 

    PATTERN SELECT SWITCH AND SPECIFIED CONDITION

    Pattern select switch Specified condition
    PWR Continuity
    NORM No continuity
    Fig 1: Checking Pattern Select Switch (PWR Mode Switch)
    G02985934Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    1. NG : Replace the pattern select switch. 
    2. OK : Go to Next Step. 
  2. Check harness and connector between terminal PWR of ECM and body ground. 

    PREPARATION: 

    1. Connect the pattern select switch connector.
    2. Disconnect the connector of ECM.

    CHECK: 

    Check continuity between terminal PWR of ECM and body ground when the pattern select switch is set to the PWR (POWER) position and NORM (NORMAL) position.

    OK: 

    PATTERN SELECT SWITCH AND SPECIFIED CONDITION

    Pattern select switch Specified condition
    PWR Continuity
    NORM No Continuity
    Fig 2: Identifying PWR Terminal Of ECM Connector
    G02985935Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

    HINT:

    The ECM uses the normal pattern signal if the PWR signal is not input.

    1. OK : Proceed to next circuit inspection shown on matrix chart (See  PROBLEM SYMPTOMS TABLE   ). 
    2. NG : Repair or replace harness or connector (See  PROCEDURE  ).