Audio & Visual System: Inspection
- INSPECT MAIN SWITCH ASSY
- Inspect the continuity between terminals at each switch position shown in TESTER CONNECTION AND SPECIFIED CONDITION .TESTER CONNECTION AND SPECIFIED CONDITION
Switch operation Tester connection Specified condition OFF 3 <=> 4 No continuity ON 3 <=> 4 Continuity If continuity is not as specified, replace the main switch assy,
- Inspect the bulb state when connecting the battery to each terminal.BATTERY CONNECTION AND SPECIFIED CONDITION
Inspection item Battery connection Specified condition Indicator Battery positive terminal <=> 3 Comes on Indicator Battery negative terminal <=> 6 Comes on Illumination Battery positive terminal <=> 1 Comes on Illumination Battery negative terminal <=> 2 Comes on If operation is not as specified, check the faulty bulb.
- Inspect continuity of the bulb by connecting the tester as shown in Fig 2.
If continuity exists, replace the main switch assy.
If no continuity exists, replace the bulb.
- Inspect the continuity between terminals at each switch position shown in TESTER CONNECTION AND SPECIFIED CONDITION .
- INSPECT POWER POINT SOCKET RELAY
- Inspect continuity between terminals according to the conditions in TESTER CONNECTION AND SPECIFIED CONDITION .TESTER CONNECTION AND SPECIFIED CONDITION
Condition Tester connection Specified condition Always 1 <=> 2 Continuity Always 3 <=> 5 No continuity Apply B+ between terminal 1 and 2 3 <=> 5 Continuity If continuity is not as specified, replace the point socket relay.
- Inspect continuity between terminals according to the conditions in TESTER CONNECTION AND SPECIFIED CONDITION .