LEMON Manuals: Even more car manuals for everyone
Home >> Lexus >> 2004 >> RX 330 AWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 546 (Door Lock) >> Front Door Lock >> Inspection

Front Door Lock: Inspection

WARNING: This page is about a different car, the 2007 Lexus RX 350. However, it is still accessible from the selected car via links, so may be relevant.
  1. INSPECT FRONT DOOR LOCK ASSEMBLY LH 
    1. Apply battery voltage to the door lock and check operation of the motor.

      OK 

      MEASUREMENT CONNECTION SPECIFIED CONDITION REFERENCE TABLE

      Measurement Condition Specified Condition
      Battery positive (+) → Terminal 4
      Battery negative (-) → terminal 1
      Lock
      Battery positive (+) → Terminal 1
      Battery negative (-) → Terminal 4
      Unlock

      HINT:

      If the result is not as specified, replace the door lock assembly.

    2. Measure the resistance according to the value(s) in the table below.

      Standard resistance 

      FRONT DOOR LOCK ASSEMBLY LH (1 OF 2)

      Tester Connection Door Lock Position Specified Condition
      7 - 8 Lock 10 kΩ or higher
      7 - 8 Unlock Below 1 Ω
      Fig 1: Identifying Front Door Lock Assembly LH
      G05140954Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

      HINT:

      If the result is not as specified, replace the door lock assembly.

    3. Measure the resistance according to the value(s) in the table below.

      Standard resistance 

      FRONT DOOR LOCK ASSEMBLY LH (2 OF 2)

      Tester Connection Condition Specified Condition
      7 - 9 ON (Door lock set to LOCK) Below 1 Ω
      7 - 9, 7 - 10 OFF (Free) 10 kΩ or higher
      7 - 10 ON (Door lock set to UNLOCK) Below 1 Ω
      Fig 2: Identifying Operation Of Door Key Lock & Unlock Switch
      G04980479Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

      HINT:

      If the result is not as specified, replace the door lock assembly.

  2. INSPECT FRONT DOOR LOCK ASSEMBLY RH 
    1. Apply battery voltage to the door lock and check operation of the motor.

      OK 

      MEASUREMENT CONNECTION SPECIFIED CONDITION REFERENCE TABLE

      Measurement Condition Specified Condition
      Battery positive (+) → Terminal 4
      Battery negative (-) → Terminal 1
      Lock
      Battery positive (+) → Terminal 1
      Battery negative (-) → Terminal 4
      Unlock

      HINT:

      If the result is not as specified, replace the door lock assembly.

    2. Measure the resistance according to the value(s) in the table below.

      Standard resistance 

      FRONT DOOR LOCK ASSEMBLY RH

      Tester Connection Door Lock Position Specified Condition
      7 - 8 Lock 10 kΩ or higher
      7 - 8 Unlock Below 1 Ω
      Fig 3: Identifying Front Door Lock Assembly RH
      G05140956Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

      HINT:

      If the result is not as specified, replace the door lock assembly.