Ventilation Valve Sub-ASSY: Replacement
- REMOVE VENTILATION VALVE SUB-ASSY
- Disconnect the PCV hose from the PCV valve.
- Remove the PCV valve.
- INSTALL VENTILATION VALVE SUB-ASSY
- Reinstall the PCV valve.
- Apply adhesive to 2 or 3 threads.
Adhesive:
Part No. 08833-00070, THREE BOND 1324 or equivalent
- Reinstall the PCV valve.
Torque: 27 N.m (275 kgf.cm, 20 ft.lbf)
- Apply adhesive to 2 or 3 threads.
- Connect the PCV hose to the PCV valve.
- Reinstall the PCV valve.