Fuel Lid Opener System: Inspection
- INSPECT FUEL LID OPENER SWITCH CONTINUITY
- Check that continuity exists between terminals with the switch ON (Lever pulled).
- Check that no continuity exists between terminals with the switch OFF (Lever free).
If continuity is not as specified, replace the switch assembly.
- INSPECT FUEL LID OPENER SWITCH CIRCUIT
Disconnect the connector from the switch and inspect the connector on the wire harness side, as shown.
TESTER CONNECTION SPECIFICATIONTester connection Condition Specified condition 1 - Ground Constant Continuity 2 - Ground Constant Battery positive voltage If circuit is not as specified, inspect the circuits connected to other parts.
- INSPECT FUEL LID OPENER SOLENOID OPERATION
- Connect the positive (+) lead from the battery to terminal 2 and negative (-) lead to terminal 3.
- Check that the solenoid operates in the fuel lid opening.
If operation is not as specified, replace the solenoid.
- INSPECT FUEL LID OPENER MOTOR CIRCUIT
Disconnect the connector from the switch and inspect the connector on the wire harness side, as shown.
TESTER CONNECTION SPECIFICATIONTester connection Condition Specified condition 3 - Ground Constant Continuity 2 - Ground Fuel lid opener switch ON (Lever pulled) Battery positive voltage If circuit is not as specified, inspect the circuits connected to other parts.