LEMON Manuals: Even more car manuals for everyone
Home >> Lexus >> 2004 >> ES 330 >> Repair and Diagnosis >> Body & Frame >> Windows >> Power Window Control System - Diagnostics >> Power Window Regulator Motor ASSY RH Limit Switch And Pulse Sensor Circuit (Passenger's Door) >> Inspection Procedure

Inspection Procedure

  1. CHECK WIRE HARNESS (LIMIT SWITCH CIRCUIT) 
    1. Disconnect the F13 power window regulator switch and P8 power window regulator motor assy RH connectors.
      Fig 1: Disconnecting Power Window Regulator Switch & Power Window Regulator Motor Assy RH
      G01437086Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    2. Check the continuity of between the disconnected connectors.

    Standard: 

    Fig 2: Checking Continuity Between Limit Switch Circuit Chart
    G01437085Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

    NG: REPAIR OR REPLACE WIRE HARNESS AND CONNECTOR 

    OK: Go to next step. 

  2. CHECK WIRE HARNESS (PULSE SENSOR CIRCUIT) 
    1. Disconnect the F13 power window regulator switch and P8 power window regulator motor assy RH connectors.
      Fig 3: Disconnecting Power Window Regulator Switch & Power Window Regulator Motor Assy RH
      G01437088Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    2. Check the continuity of between the disconnected connectors.

    Standard: 

    Fig 4: Checking Continuity Between Pulse Sensor Circuit Specifications Chart
    G01437087Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

    NG: REPAIR OR REPLACE WIRE HARNESS AND CONNECTOR 

    OK: Go to next step. 

  3. REPLACE POWER WINDOW REGULATOR MOTOR ASSY RH 
    1. Replace the power window regulator motor assy RH.
    2. Check the power window operation.

    OK: END 

    NG: REPLACE POWER WINDOW REGULATOR SWITCH ASSY