Inspection Procedure

  1. CHECK WIRE HARNESS (LIMIT SWITCH CIRCUIT) 
    1. Disconnect the D17 power window regulator master switch and P7 power window regulator motor assy LH connectors.
      Fig 1: Disconnecting Power Window Regulator Master Switch & Power Window Regulator Motor Assy LH
      G01437081Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    2. Check the continuity between the disconnected connectors.

    Standard: 

    Fig 2: Checking Continuity Between Limit Switch Circuit Specifications Chart
    G01437080Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

    NG: REPAIR OR REPLACE WIRE HARNESS AND CONNECTOR 

    OK: Go to next step. 

  2. CHECK WIRE HARNESS (PULSE SENSOR CIRCUIT) 
    1. Disconnect the D17 power window regulator master switch and P7 power window regulator motor assy LH connectors.
      Fig 3: Disconnecting Power Window Regulator Master Switch & Power Window Regulator Motor Assy LH
      G01437083Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    2. Check the continuity between the disconnected connectors.

    Standard: 

    Fig 4: Checking Continuity Between Pulse Sensor Circuit Specifications Chart
    G01437082Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

    NG: REPAIR OR REPLACE WIRE HARNESS AND CONNECTOR 

    OK: Go to next step. 

  3. REPLACE POWER WINDOW REGULATOR MOTOR ASSY LH 
    1. Replace the power window regulator motor assy LH.
    2. Check the power window operation.

    OK: END 

    NG: REPLACE POWER WINDOW REGULATOR MASTER SWITCH ASSY