Wireless Door Lock Buzzer
Inspect the wireless door lock buzzer operation. Connect the positive (+) lead from the ohmmeter to terminal 1 and the negative (-) lead to terminal 2, and measure resistance of approximately 1000 ohms. See CONNECTOR IDENTIFICATION . If resistance is not as specified, replace the buzzer.