Inspection Procedure

  1. Check pattern select switch (PWR mode switch). 

    PREPARATION: 

    Disconnect the pattern select switch connector.

    CHECK: 

    Check continuity between terminals 3 and 5 of pattern select switch connector when the select switch is set to PWR and NORM positions.

    OK: 

    SPECIFIED CONDITION CHART

    Pattern select switch Specified condition
    PWR Continuity
    NORM No continuity
    Fig 1: Checking Pattern Select Switch (PWR Mode Switch)
    G03374605Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    1. NG : Replace the pattern select switch. 
    2. OK : Go to next step 
  2. Check PATTERN SEL SW signal. 

    PREPARATION: 

    1. Connect the pattern select switch connector.
    2. Turn the ignition switch ON.

    CHECK: 

    Measure voltage between terminal PWR of ECM and body ground when the pattern select switch is set to the PWR (POWER) position and NORM (NORMAL) position.

    OK: 

    PATTERN SELECT SWITCH CHART

    Pattern select switch Voltage
    PWR Below 1.5 V
    NORM 10-14 V

    HINT:

    The ECM uses the normal pattern signal if the PWR signal is not input.

    Fig 2: Checking Pattern Sel SW Signal
    G03374606Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    1. OK : Proceed to next circuit inspection shown on matrix chart (See  PROBLEM SYMPTOMS TABLE  ). 
    2. NG : Repair or replace harness or connector (See  HOW TO USE THE DIAGNOSTIC CHART AND INSPECTION PROCEDURE  ).