  1. CLOSE BOTH HAND VALVES OF MANIFOLD GAUGE SET 
  2. DISCONNECT QUICK DISCONNECT ADAPTERS FROM SERVICE VALVES ON REFRIGERANT LINE 

    HINT:

    Slide the sleeve of the quick disconnect adapter upward to unlock the adapter and remove it from the service valve.

  3. INSTALL CAPS TO SERVICE VALVES ON REFRIGERANT LINES 
    Fig 1: Disconnecting Quick Disconnect Adapters From Service Valve
    G01317247Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002