Testing Fuel Pump Relay (IS300, LS430 & SC430)
For relay terminal identification, see Fig 1. If relay continuity is not as specified, replace relay and retest system.
- Continuity should exist between terminals No. 1 and 2.
- Continuity should not exist between terminals No. 3 and 4.
- Apply battery voltage across terminals No. 1 and 2. Continuity should exist between terminals No. 3 and 4.