Service Data
STARTING & CHARGING SERVICE DATA
| Starter | Rated voltage and output power | 12 V 2.0 kW | ||
| No-load characteristics | Current | 100 A or less at 11.5 V | ||
| Brush length | Standard | 15.0 mm (0.591 in.) | ||
| Minimum | 9.0 mm (0.354 in.) | |||
| Spring installed load | Standard | 21.5 - 27.5 N (2.2 - 2.8 kgf, 4.8 - 6.2 lbf) | ||
| Minimum | 12.7 N (1.3 kgf, 2.9 lbf) | |||
| Commutator | Diameter | Standard | 35.0 mm (1.378 in.) | |
| Minimum | 34.0 mm (1.339 in.) | |||
| Undercut depth | Standard | 0.7 mm (0.028 in.) | ||
| Minimum | 0.2 mm (0.008 in.) | |||
| Circle runout | Maximum | 0.05 mm (0.0020 in.) | ||
| Field frame | Shunt coil resistance | at 20°C (68°F) | 1.5 - 1.9 ohm | |
| Battery | Maintenance-free Voltage | at 20°C (68°F) | 12.5-12.9V | |
| Generator | Rated output | 12V 130A | ||
| Rotor coil resistance | at 20 °C (68°F) | 2.3 - 2.7 ohm | ||
| Slip ring diameter | Standard | 14.2 - 14.4 mm (0.559 - 0.567 in.) | ||
| Minimum | 14.0 mm (0.551 in.) | |||
| Brush exposed length | Standard | 10.5 mm (0.413 in.) | ||
| Minimum | 4.5 mm (0.177 in.) | |||
| Voltage regulator | Regulating voltage | 13.2-14.8 V | ||