Light Control Switch
Inspect the light control switch continuity. For combination switch connector view, see CONNECTOR IDENTIFICATION . See INSPECTING LIGHT CONTROL SWITCH CONTINUITY table. If the continuity is not as specified, replace the switch. See COMBINATION SWITCH under REMOVAL & INSTALLATION.
INSPECTING LIGHT CONTROL SWITCH CONTINUITY
| Switch Position | Tester Connection | Specified Condition |
|---|---|---|
| OFF | ..... | No Continuity |
| TAIL | 15 - 16 | Continuity |
| HEAD | 14 - 15 - 16 | Continuity |
| AUTO | 13 - 16 | Continuity |