Light Control Switch
Inspect the light control switch continuity. See CONNECTOR IDENTIFICATION . See INSPECTING LIGHT CONTROL SWITCH CONTINUITY table. If continuity is not as specified, replace the combination switch. See COMBINATION SWITCH under REMOVAL & INSTALLATION.
INSPECTING LIGHT CONTROL SWITCH CONTINUITY
| Switch Position | Tester Connection | Specified Condition |
|---|---|---|
| OFF | ..... | No Continuity |
| TAIL | 14 - 16 | Continuity |
| HEAD | 13 - 14 - 16 | Continuity |
| AUTO | 12 - 16 | Continuity |