Brake Fluid Level Warning Switch
Remove the reservoir tank cap and strainer. Disconnect the connector. See Fig 1. Check that no continuity exists between the terminals with the switch OFF (float up). Use siphon, etc. to take fluid out of the reservoir tank. Check that continuity exists between the terminals with the switch ON (float down). Pour the fluid back in the reservoir tank. If operation is not as specified, replace the switch.