Blower Motor Circuit
- Remove blower motor. See BLOWER MOTOR under REMOVAL & INSTALLATION. Using a fused jumper wire, connect battery voltage to blower motor connector terminal No. 2 (Red wire). Connect terminal No. 1 (Black wire) to ground. If blower motor operates smoothly, go to next step. Replace blower motor if it does not operate smoothly.
- Remove A/C-heater control assembly, leaving connectors connected. Check pulse signal between terminal A18-5 (Light Green/Red wire) and A21-22 (White/Black wire). If pulse signal is not present, replace A/C-heater control assembly.
- If pulse signal is present, inspect wiring between battery and blower motor, and between blower motor and ground. Repair as necessary. If wiring is okay, replace blower controller.