LEMON Manuals: Even more car manuals for everyone
Home >> Lexus >> 1997 >> LS 400 >> Repair and Diagnosis >> Electrical >> Gauges >> Instrument Panel >> Instrument Cluster Circuit Tests

Instrument Cluster Circuit Tests

NOTE: Unless specified otherwise, use a DVOM with a minimum input impedance of 10-megohms during testing.

Disconnect instrument cluster harness connectors "A", "B", "C" and "D". See Figure and Fig 1 . Using DVOM, test each circuit from harness side of appropriate connector under condition listed. See INSTRUMENT CLUSTER INPUT CIRCUIT TEST  table.

Fig 1: Identifying Instrument Cluster Harness Connector Terminals
G96J07421Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
INSTRUMENT CLUSTER INPUT CIRCUIT TEST

DVOM Connection Condition Specification
Twin Trip & ODO Switch
A1 & B4 ODO/TRIP Switch Free No Continuity
A1 & B4 ODO/TRIP Switch Pushed Continuity
A2 & B4 RESET Switch Free No Continuity
A2 & B4 RESET Switch Pushed Continuity
DOME Fuse
B2 & GND Constant Batt. Voltage
Park/Neutral Switch
C4 & GND Ign. On, Selector In "P" Position Batt. Voltage
C5 & GND Ign. On, Selector In "R" Position Batt. Voltage
C16 & GND Ign. On, Selector In "N" Position Batt. Voltage
D1 & GND Ign. On, Selector In "D" Position Batt. Voltage
D2 & GND Ign. On, Selector In "3" Position Batt. Voltage
D3 & GND Ign. On, Selector In "2" Position Batt. Voltage
C12 & GND Ign. On, Selector In "L" Position Batt. Voltage
Generator "L" Terminal
D13 & GND Engine Off Continuity
D13 & GND Engine Running Batt. Voltage
Fuel Gauge Sender
D21 & B5 Float Position Full About 4.6 Volts
D21 & B5 Float Position 1/2 About 2.4 Volts
D21 & B5 Float Position Empty About 0.3 Volts
D21 & D22 Ign. On About 5.0 Volts
Turn Signal & Hazard Switch
C15 & GND Hazard Switch On Fluctuates 0-Batt. Volts
C15 & GND Ignition ON, Turn Switch: Right Turn Fluctuates 0-Batt. Volts
C11 & GND Hazard Switch On Fluctuates 0-Batt. Volts
C11 & GND Ignition ON, Turn Switch: Left Turn Fluctuates 0-Batt. Volts
Headlight Switch
B7 & C13 Headlights On, Dimmer Low No Voltage
B7 & C13 Headlights On, Dimmer High Or Flash Batt. Voltage
Ignitor
B3 & GND Engine Running Voltage Fluctuates
Pattern Select Switch
B9 & B1 Ign. On, Pattern Switch PWR Batt. Voltage
Oil Level Warning Switch
D17 & GND Oil Temp. Above 131°F, Float Down No Continuity
D17 & GND Oil Temp. Below 131°F Continuity
D17 & GND Oil Temp. Above 131°F, Float Up Continuity
Ground
B12 & GND Constant Continuity
B5 & GND Constant Continuity
GAUGE Fuse
B1 & GND Ign. Switch ACC, START No Voltage
B1 & GND Ign. Switch ON Batt. Voltage
PWR-IG Fuse
B6 & GND Ign. Switch LOCK, ACC, START No Voltage
B6 & GND Ign. Switch ON Batt. Voltage
Light Control Rheostat
A7 & GND Lights On, Turn Rheostat Varying Voltage