DTC C105B-01: Actuator Circuit Group B - General electrical failure: Action
- Refer to the appropriate system wiring diagrams and check the chassis control module continuously variable damper power supply fuse and circuit - Circuit reference VBATT CVD - For short circuit to ground, short circuit to power, open circuit, high resistance. Repair circuit as required, clear the DTCs and retest
- Refer to the appropriate system wiring diagrams and check the suspension damper solenoid circuits for short circuit to ground, short circuit to power, open circuit, high resistance. Repair circuit as required, clear the DTCs and retest