Possible Causes
NOTE:
- Monitor description. Short circuit detected by the ignition control module, passed to main CPU within powertrain control module and sets the DTC
- This DTC is set when the powertrain control module has detected a ground measurement for a period longer than expected or has detected a ground measurement when another value was expected.
- Ignition coil circuit, short circuit to ground