DTC B1429-11: Right Front Cooled/Heated Seat Module Blower #2 Motor Speed Control - Circuit short to ground: Action
- Refer to the appropriate SYSTEM WIRING DIAGRAMS information and check the front right climate seat cushion blower control circuit for short circuit to ground. Repair the wiring harness or install a new seat cushion climate assembly as necessary