DTC B10C0-53: Fuel Pump Power Supply - Deactivated: Action
NOTE:
This DTC indicates that the fuel pump has been disabled diagnostically to protect the in-tank fuel pump from dry running following replacement of the fuel tank or replacement of the central junction box
- Ensure there is sufficient fuel in the fuel tank to submerge the in-tank fuel pump (minimum of 10 liters). Using the manufacturer approved diagnostic system, re-configure the central junction box with the latest level software