DTC C2007-18: Right Motor - Circuit Current Below Threshold: Action
- Refer to the appropriate system wiring diagram and check the right electric park brake actuator motor supply fuse. Rectify as necessary
- Refer to the appropriate system wiring diagram and check the electric park brake control module ground circuit for open circuit, high resistance
- Test the battery voltage and charging system. Repair charging system as necessary, clear DTC and re-test
- Refer to the appropriate system wiring diagram and check the right electric park brake actuator circuit for short circuit to ground, short circuit to power, open circuit, high resistance
- Switch ignition off and on. Apply and release the electric park brake using the electric park brake switch. Clear the DTC and re-test. If the fault is not reset, suspect electric park brake actuator fault. Install a new electric park brake actuator as necessary
- Switch ignition off and on. Apply and release the electric park brake using the electric park brake switch. Clear the DTC and re-test. If the fault is not reset, suspect electric park brake control module fault. Install a new electric park brake control module as necessary