DTC C1A36-11: Exhaust Valve - Circuit short to ground: Action
WARNING: This page is about a different car, the 2015 Jaguar XF, 2014 Jaguar XF, and 2013 Jaguar XF. However, it is still accessible from the selected car via links, so may be relevant.
- Refer to the applicable SYSTEM WIRING DIAGRAM(S) and check the exhaust valve circuit for short circuit to ground, open circuit, high resistance. Repair circuit as required, clear DTC and retest
- If fault persists, check integrity of exhaust valve connector. Repair or replace as required. Clear DTC and retest
- If fault persists, check and install a new exhaust valve as required. Clear DTC and retest
- If fault persists, check and install a new integrated suspension control module as required. Clear DTC and retest