Unlock Condition
The unlock release pressure is supplied via the control valve to the lock-up clutch. See Fig 1 . The pressure forces the clutch mechanism away from the torque converter and moves the lock-up mechanism into the unlock condition. The torque converter pressure is decayed to the drain port, removing the applied pressure from the torque converter, allowing the clutch mechanism to move.