Service Data: Actuators
Injector
- Specification
| Item | Specification |
|---|---|
| Coil Resistance (Ω) | 1.3 - 1.43 [20°C(68°F)] |
ETC Motor [integrated into ETC Module]
- Specification
| Item | Specification |
|---|---|
| Coil Resistance (Ω) | 1.1 - 1.7 [20°C(68°F)] |
| Operation Voltage (V) | 7.7 - 16.0 |
Purge Control Solenoid Valve (PCSV)
- Specification
| Item | Specification |
|---|---|
| Coil Resistance (Ω) | 18.5 - 22.5 [20°C(68°F)] |
| Operation Voltage (V) | 9 - 16 |
| Rated current (A) | 0.66 |
Variable Force Solenoid (VFS) [Bank 1, 2/Intake]
- Specification
| Item | Specification |
|---|---|
| Coil Resistance (Ω) | 7.0 - 8.0 [20°C(68°F)] |
| Operation Voltage (V) | 10 - 16 |
CVVT Oil Control Valve (OCV) [Bank 1, 2/Exhaust]
- Specification
| Item | Specification |
|---|---|
| Coil Resistance (Ω) | 9.4 - 10.4 [20°C(68°F)] |
| Supply Voltage (V) | 10 - 16 |
Variable Intake Solenoid (VIS) Valve
- Specification
| Item | Specification |
|---|---|
| Coil Resistance (Ω) | 30.0 - 35.0 [20°C(68°F)] |
| Operation Voltage (V) | 9 - 16 |
| pin | 2 |
Fuel Pressure Control Valve (FPCV)
- Specification
| Item | Specification |
|---|---|
| Coil Resistance (Ω) | 1.09 - 1.21 [20°C(68°F)] |
| Supply Voltage (V) | 6.5 |
Canister Close Valve (CCV)
| Item | Specification |
|---|---|
| Coil Resistance (Ω) | 19.8 - 21.8 (20°C) |