If a part of the head up display footage is distorted or it is not at eye level with the driver a Global Diagnostic System (KDS) can be used to carry out calibration.

  1. Calibration is required:
    • After replacing the head-up display unit
    • When the footage is distorted after replacing the windshield (double vision removal film built-in glass)
    • When the HUD mounted main crash pad is removed/installed or replaced.
    • When the image setting location of the HUD unit is not at eye level of the driver resulting in out of focus image.
  2. Calibration items
    No Footage calibration functions Calibration cases
    1 Rotation: Calibrate in counterclockwise/clockwise direction at the center.
    G13128704Courtesy of KIA MOTORS AMERICA, INC.
    2 Smile: Calibrate vertically at the center.
    G13128705Courtesy of KIA MOTORS AMERICA, INC.
    3 Slanted (up/down): Calibrate along a vertical inclination.
    G13128706Courtesy of KIA MOTORS AMERICA, INC.
    4 Slanted (left/right): Calibrate along a horizontal inclination.
    G13128707Courtesy of KIA MOTORS AMERICA, INC.
    5 Parallel compensation
    G13128708Courtesy of KIA MOTORS AMERICA, INC.
    6 Up/down movement of indicated location: Calibrate to user eye level.
    G13128709Courtesy of KIA MOTORS AMERICA, INC.
    7 Initialization: Return to previous status before calibration.  
  3. Process of calibration
    1. Locate the vehicle on a flat plane for accurate adjustment.
    2. Make sure that there are no foreign materials on the windshield.
    3. Connect the Global Diagnostic System to the vehicle, and select vehicle type and HUD system additional functions.
    4. Under additional functions select 'HUD calibration'.
      G13128710Courtesy of KIA MOTORS AMERICA, INC.
      G13128711Courtesy of KIA MOTORS AMERICA, INC.
    5. Before 'calibration', carry out 'HUD calibration - initialization'.
      NOTE: 'HUD calibration - initialization' must be performed prior to 'calibration'.
      G13128712Courtesy of KIA MOTORS AMERICA, INC.
    6. Select the necessary calibration items and carry out 'HUD calibration'.
      G13128713Courtesy of KIA MOTORS AMERICA, INC.
    7. When calibration is completed, start and cut off the engine and check that the footage calibration is completed.