LEMON Manuals: Even more car manuals for everyone
Home >> Kia >> 2019 >> Stinger Base, AWD >> Repair and Diagnosis >> Engine Performance >> Engine Control Systems >> Idle Stop & Go ISG System - 2.0L >> Starter >> Repair Procedures >> Inspection >> Free Running Inspection

Free Running Inspection

  1. Place the starter motor in a vise equipped with soft jaws and connect a fully-charged 12-volt battery to starter motor as follows.
  2. Connect a test ammeter (150-ampere scale) and carbon pile rheostats shown is the illustration below.
  3. Connect a voltmeter (15-volt scale) across starter motor.
    G12792475Courtesy of KIA MOTORS AMERICA, INC.
  4. Rotate carbon pile to the off position.
  5. Connect the battery cable from battery's negative post to the starter motor body.
  6. Adjust until battery voltage shown on the voltmeter reads 11.5 volts.
  7. Confirm that the maximum amperage is within the specifications and that the starter motor turns smoothly and freely.
Current (Max.) Speed (Min.)
100 A 1, 915 rpm