DTC Information: DTC Detecting Condition
WARNING: This page is about a different variant/trim than selected.
| Item |
Detecting Condition |
Possible cause |
| DTC Strategy |
- CAN communication monitoring
|
Under wake condition
- Open or short in CAN high line
- Open or short in CAN low line
- Shorted circuit between CAN high and low line
CAUTION:
CAN high has ground voltage and CAN low has battery voltage during sleep condition.
|
| Enable Conditions |
- Ignition "ON" and power is supplied to SMK unit
- Short to battery in CAN high line
- Short to battery in CAN low line
- Short to ground in CAN high line
- Short to ground in CAN low line
- Shorted circuit between CAN high and low line
- Short to 5V power in CAN high line
- Open in CAN high line
- Open In CAN low line
|
| Threshold value |
- CAN high:
CAN high line is shorted to ground if voltage in CAN high line is 0V.
CAN high line is shorted to power if voltage in CAN high line is B+
- CAN low:
CAN low line is shorted to ground if voltage in CAN high line is 0V.
CAN low line is shorted to power if voltage in CAN high line is B+
|
| Diagnostic Time |
- Fault continues for 2s under normal battery voltage (9 to 16V)
|
| DTC Erasing Time |
- Immediately if fault is cleared under normal battery voltage. (Active DTC)
- 30 Ignition cycles (Ignition switch ON to OFF (History DTC)
|