Component Inspection
| Inspection Condition | (+) Probe | (-) Probe | Specification | ||
|---|---|---|---|---|---|
| Connector | Terminal | Connector | Terminal | ||
|
Knock Sensor #1 (Component Side) | 2 (Signal) | Knock Sensor #1 (Component Side) | 1 (Ground) | Approx. 4.87MΩ at 68°F(20°C) |
Good
- Go to "Verification of Repair " procedure.
No Good
- Carefully re-do this troubleshooting guide steps.
- If no problems were found with the circuits or connectors, replace the Knock Sensor #1 and go to "Verification of Repair " procedure.