G-Sensor Calibration
NOTE:
If the SRSCM is replaced always perform lateral G sensor calibration.
- Ignition "OFF", connect GDS.
- Ignition "ON" & Engine "OFF" select vehicle name and ESC system.
- Perform G-sensor calibration.
- Perform the "G-Sensor Calibration" procedure with GDS.
- Complete the "G-Sensor Calibration" procedure.