UNDERDRIVE BRAKE CONTROL SOLENOID VALVE (UD/B_VFS) SPECIFICATIONS

Item Specification
Control type N/H (Normal High)
Control pressure (kp a (kgf/cm2 , psi)) 500.14 - 9.81 (5.1 - 0.1, 72.54 - 1.42)
Currency (mA) 50 - 850
Coil resistance (Ω) 5.1 ± 0.3