Signal Circuit Inspection
- Ignition "OFF".
- Refer to HEATED OXYGEN SENSOR (HO2S) and disconnect Upstream O2 Sensor connector.
- Ignition "ON"
- Measure voltage between Pin No. 3 (V_IP) terminal of Upstream O2 Sensor harness connector and chassis ground.
- Measure voltage between Pin No. 2 (V_N) terminal of Upstream O2 Sensor harness connector and chassis ground.
- Measure voltage between Pin No. 1 (V_G) terminal of Upstream O2 Sensor harness connector and chassis ground.
- Measure voltage between Pin No. 6 (V_RC) terminal of Upstream O2 Sensor harness connector and chassis ground.
Specification : Pin No. 3 (V_IP): 2.6V/Pin No. 2 (V_N): 2.1V/Pin No. 1 (V_G): 2.1V/Pin No. 6 (V_RC): 2.6V
- Is the measured value within specification?
YES
- Go to "Component Inspection " procedure.
NO
- Repair open or short in signal circuit between Upstream O2 Sensor and ECM/PCM and then go to "Verification of Vehicle Repair " procedure.