Operating Logic Test (Manual only)
Inspect the PTC operation with the confirmation logic below:
- Entering
- Set the Floor mode and maximum heating position.
- Turn off the blower switch.
- Press the intake (recirculation) button continually 5 seconds more.
- The intake and A/C button indicator will continuously flash with an interval of 0.5 seconds.
- Confirm the PTC operation by turning on the blower switch after 3 seconds.
- The logic test will automatically cancelled after 30 seconds.
In addition, it can be cancelled by doing the followings:
- Select A/C or intake (recirculation) switch
- Ignition switch OFF
- Cancellation
- Select A/C or intake (recirculation) switch.
- Turn the ignition switch OFF.
- The test cancels automatically after 30 seconds.
- If the PTC does not operate, substitute with a known-good PTC heater and check for proper operation.
If the problem is corrected, replace the PTC heater.