LEMON Manuals: Even more car manuals for everyone
Home >> Kia >> 2016 >> Optima Hybrid >> Repair and Diagnosis >> Transmission >> Automatic Trans >> Automatic Transaxle System - General Information (HEV) >> Automatic Transaxle System >> Specifications >> Solenoid Valves

Solenoid Valves

Direct control VFS [26/B, E/C] 

Control type: Normal low type

Control Pressure kpa (kgf/cm2 , psi) 9.81 ~ 500.14 (0.1 ~ 5.1, 1.42 ~ 72.54)
Current value (mA) 50 ~ 850
Internal resistance (Ω) 5.1

Direct control VFS [UD/B, OD/C, 35R/C] 

Control Type: Normal high type

Control Pressure kpa (kgf/cm2 , psi) 500.14 ~ 9.81 (5.1 ~ 0.1, 72.54 ~ 1.42)
Current value (mA) 50 ~ 850
Internal resistance (Ω) 5.1

Line Pressure Control VFS 

Control type: Normal high type

Control Pressure kpa (kgf/cm2 , psi) 500.14 ~ 9.81 (5.1 ~ 0.1, 72.54 ~ 1.42)
Current value (mA) 50 ~ 850
Internal resistance (Ω) 5.1

ON/OFF Solenoid Valve (SS-A, SS-B) 

Control type: Normal low type

Control pressure kpa (kgf/cm2 , psi) 490.33(5.0, 71.12)
Internal resistance (Ω) 10 ~ 11