Repair Procedures: Inspection
- Turn the ignition switch ON.
- Manually operate the control switch and measure the voltage of the blower motor.
- Select the control switch to raise the voltage until high speed.
Specification
Fan Speed Motor Voltage (V) Manual Fan Speed Auto Fan Speed 1 3.4 Max. 4.5 2 4.9 4.5 ~ 5.5 3 6.1 5.5 ~ 6.7 4 7.2 6.7 ~ 7.7 5 8.3 7.7 ~ 8.9 6 9.5 8.9 ~ 10.1 7 11.3 10.1 ~ 11.3 8 B+ * Manual Fan Speed: 3.4V ~ B+
* Auto Fan Speed: 4.5V ~ B+
- If the measured voltage is not within specification, substitute with a known-good power mosfet and check for proper operation.
- Replace the power mosfet if it is proved that there is a problem with it.