LEMON Manuals: Even more car manuals for everyone
Home >> Kia >> 2016 >> Forte EX >> Repair and Diagnosis >> Brakes >> Traction Control >> Electronic Stability Control (ESC) System >> Schematic Diagrams >> ESC Connector Input/Out put

ESC Connector Input/Out put

Fig 1: ESC Connector Terminal Input/Output
G11795816Courtesy of KIA MOTORS AMERICA, INC.
Wire No. Designation Current max.permissible wire resistance R_L (mΩ)
max min
13 Ground for recirculation pump 39 A 10 A -
38 Ground for solenoid valves and ECU 15 A 2 A -
1 Voltage supply for pump motor 39 A 10 A -
25 Voltage supply for solenoid valves 15 A 2 A -
32 Voltage for hybrid ECU (IGN) 1 A 500 mA 60
22, 6, 20, 31 signal wheel speed sensor FL, FR, RL, RR 16.8 mA 5.9 mA 250
34, 18, 33, 19 Voltage supply for the active wheel speed sensor FL, FR, RL, RR 16.8 mA 5.9 mA 250
30 Brake light switch (Signal) 10 mA 5 mA 250
14 CAN Low 30 mA 20 mA 250
26 CAN High 30 mA 20 mA 250
27 Wheel speed sensor output Open Drain - -
8 ESC Passive switch (Signal) 10 mA 5 mA 250
4 ESS output signal 200 mA 100 mA 150
16 Brake lamp actuator input signal 200 mA 100 mA 150
10 Parking brake switch signal 10 mA 5 mA 250
23 Clutch switch 10 mA 5 mA 250