Measuring Resistance
- Disconnect the cruise control switch connector from the control switch.
- Measure resistance between terminals on the control switch when each function switch is ON (switch is depressed).
Function switch Terminal Resistance (±5%) [kΩ] CANCEL 2 - 7 0.18 SET- 2 - 7 0.33 RESUME+ 2 - 7 0.55 CRUISE 2 - 7 0.88 SCC 2 - 7 2.54 - If not within specification, replace switch.