LEMON Manuals: Even more car manuals for everyone
Home >> Kia >> 2012 >> Sorento SX, FWD >> Repair and Diagnosis >> Engine Performance >> Engine Control Systems >> Engine Control System - 3.5L >> Variable Intake Solenoid (VIS) Valve >> Description and Operation >> Description

Description and Operation: Description

Variable Intake manifold Solenoid (VIS) valves are installed on the intake manifold (VIS Valve 1) and the surge tank (VIS Valve 2). These VIS valve 1 and 2 control vacuum modulators which activate valves in the intake manifold and the surge tank. These valves are opened or closed by ECM according to engine condition (Refer to below table).

Fig 1: Identifying Variable Intake Solenoid Valve
G07419577Courtesy of KIA MOTORS AMERICA, INC.
ENGINE CONDITION CHART

Engine Condition VIS Valve #1 (In-manifold) VIS Valve #2 (Surge Tank)
Low Speed Open Open
Medium Speed Close Close
High Speed Close Open
High End Speed Open Open