Charging System Test Procedure
- Press ENTER to begin charging system test.
- If ENTER button is pressed, the tester displays the actual voltage of alternator.
Press ENTER to test the charging system.
- Turn off all electrical load and rev engine for 5 seconds with pressing the accelerator pedal.
- Press ENTER.
- The MICRO 570 analyzer charging system output at idle for comparison to other readings.
- Take a relevant action according to the test results by referring to the table below after shutting off the engine and disconnect the tester clamps from the battery.
Charging System Test Results
CHARGING SYSTEM TEST RESULTS CHARTResult On Printer Remedy Charging system normal/Diode ripple normal Charging system is normal No charging voltage Alternator does not supply charging current to battery - Check belts, connection between alternator and battery
Replace belts or cable or alternator as necessaryLow charging voltage Alternator does not supply charging current to battery and electrical load to system fully - Check belts and alternator and replace as necessary
High charging voltage The voltage from alternator to battery is higher than normal limit during voltage regulating. - Check connection and ground and replace regulator as necessary
- Check electrolyte level in the battery
Excess ripple detected One or more diodes in the alternator is not functioning properly - Check alternator mounting and belts and replace as necessary