Component Inspection
- Check FTPS
- Key "ON".
- Disassemble FTPS. (Don't disconnect FTPS connector.)
- Connect the vacuum gauge.
- Measure the output voltage with using the vacuum gauge.CAUTION: Be careful while you do this procedure. FTPS would be damaged if you apply vacuum excessively.
- Specification :
SPECIFICATION CHARTFTPS Normal Parameter Gauge pressure -66.66 hpa (-139.2 lbf/ft2 ) 0 hpa 66.66 hpa (139.2 lbf/ft2 ) Voltage 0.5 V 2.5 V 4.5 V
- Is the measured voltage within specification?
YES
- Substitute with a known-good PCM and check for proper operation. If the problem is corrected, replace PCM and then go to "VERIFICATION OF VEHICLE REPAIR " procedure.
NO
- Substitute with a known-good FTPS and check for proper operation. If the problem is corrected, replace FTPS and then go to "VERIFICATION OF VEHICLE REPAIR " procedure.